COOLING UNIT GENERAL SPECS:
- Cooled down the power converter & transformer in an Emu
- Roof mounted
- Heat dissipation 28kw
- 1652x1330x765mm
- 296KG
RADIATORS:
SYSTEM:
- AXIAL FAN & 7,5KW MOTOR
- MOTOR SELECTED BASED ON 1500(PA) AIR PRESSURE DROP
MORE DETAILS
- Aluminium based frame for weight reduction
- Cl1 certification
- In-house manufacturing
- Specific coating requirement from customer
- Fea & fatigue analysis simulations based on railway norms